TL602E-10: 12V-10VA Class 2 electronic Driver/Transformer
¥ IC rated for recessed applications and can be buried in
insulation ¥ Rated for 0.5-10 watts total load ¥ 120VAC input
¥ Ideally suited for driving Juno Mini LED Downlight/Gimbal and
Solo-Task fixtures ¥ May also be used to operate other low
wattage LED or incandescent loads.
Construction 18 gauge die formed steel housing ¥ Low-profile, 1Ó
overall height ¥ Available in standard direct-wire and optional 6Õ 3-wire
cord & plug version ¥ Terminal block provided for direct wire inputs
accepts 18-12 AWG ¥ All versions provided with terminal block on
output side for quick and secure fixture wiring (Type CL2 or NEC
equivalent 18-12 AWG) ¥ Direct-wire versions supplied with die-cast
fitting for 3/8Ó flexible metal conduit ¥ White polyester powder coat paint
finish.
Dimming May be dimmed using only dimmers that have been tested
and qualified by Juno for use with Juno LED fixtures.
Installation Transformer should be located within 4' of first fixture
in run ¥ To avoid excessive voltage drop in light output, make sure the
fixture voltage at the last fixture is at least 10 volts ¥ Fully loaded run
lengths longer than 18Õ with 12 AWG is not recommended due to
voltage drop ¥ Terminal block wiring connections for simpler, faster
installation ¥ Provision for ground wire attachment ¥ Two 1/2Ó #6 wood
screws provided for mounting to wood surfaces ¥ IC rated for use in
insulated or non-insulated applications.
Labels cULus Listed for use in the U.S. (UL 2108) and Canada (CSA C22.2 No. 250.0) ¥ Suitable for damp locations.
For specification sheet click here - PDF
![]() |
![]() |
![]() |
![]() |
Company Information Contact Us Customer Reviews Security Certifications Line Card - PDF |
Customer Service Return Policy Shipping & Delivery Process Frequenty Asked Questions Price Match |
Coupons and Specials Promotional Coupons Free Ground Shipping Limited Time Offers Buyer Protection |
![]() |
|
|
|
|