This clamp on meter is a combination power analyzer, power quality logger, and clamp meter, and is ideal for monitoring electronic loads.
With the bright color power meter display to analyze the harmonic spectrum, a low-pass filter to remove high frequency noise, and a high EMC immunity design, the Fluke 345 power analyzer is ideal for troubleshooting power quality on switching loads. Additionally, the Hall Effect clamp meter design makes measurement of dc current possible without the need to break the circuit with the power meter. The internal memory of the power analyzer enables long-term power quality logging for analysis of trends or intermittent problems.
Applications
Features
Display |
Color transmissive LCD 320 x 240 pixels (70 mm diagonal) with 2 level backlight |
Power supply | ||
Battery type 1.5 V Alkaline AA MN 1500 or IEC LR6 x 6 | ||
Battery life typically | > 10 hours
(backlight on full) > 12 hours (backlight reduced) |
|
Battery Eliminator BE345 | Input | 110/230 V 50/60 Hz |
Output | 15 V dc, 300 mA |
Electrical safety | ||
Safety IEC 61010-1 600 V CAT IV double or reinforced insulation, pollution degree 2 | ||
Protection IP40; EN60529 | ||
Maximum safe working voltages | Current measurement | 600 V ac rms or dc between uninsulated conductor and ground |
Voltage measurement | 600 V ac rms or dc between either input terminal and ground, or 825 V between energized phase voltages (delta power config.) |
EMC | |
Emission | IEC/EN 61326-1:1997 class A |
Immunity | IEC/EN 61326-1:1997 Annex C Performance Criterion B |
Mechanical | |
Dimensions (length x width x depth) | 300 mm x 98 mm x 52 mm (12 in x 3.75 in x 2 in) |
Weight including batteries | 820 g/1.8 lb |
Jaw opening | 60 mm |
Jaw capacity | 58 mm diameter |
Cleaning | The unit can be cleaned with an Isopropanol impregnated cloth. Do not use abrasives or other solvents. |
Current measurement (dc, dc rms, ac rms) | |
Measuring range | 0 to 2000 A dc or 1400 ac rms |
Autorange facility | 40 A / 400 A / 2000 A |
Resolution | 10 mA in 40 A range 100 mA in 400 A range 1 A in 2000 A range |
Accuracy: DC and dc rms | I > 10 A: ± 1.5 % rdg ± 5
digits I < 10 A: ± 0.2 A |
Accuracy: AVG | I > 10 A: ± 3 % rdg ± 5
digits I < 10 A: ± 0.5 A |
Accuracy: Pk | I > 10 A: ± 5 % rdg ± 5
digits I < 10 A: ± 0.5 A |
Accuracy: AHr | I > 10 A: ± 2 % rdg ± 5
digits I < 10 A: ± 0.5 AHr |
Accuracy: CF (Crest Factor) | 1.1 ≤ CF < 3: ± 3 % rdg ±
5 digits 3 ≤ CF < 5: ± 5 % rdg ± 5 digits Resolution: 0.01 |
Accuracy: RPL (Ripple) | 2 % ≤ RPL < 100 %: ± 3 %
rdg ± 5 digits 100 % ≤ RPL < 600 %: ± 5 % rdg ± 5 digits Resolution: 0.1 % Idc > 5 A, Iac > 2 A |
All measurements dc and 15 Hz to 1 kHz Maximum overload 10,000 A or rms x frequency < 400,000 Amps rms is a true-rms measurement (ac + dc) |
Voltage measurement (dc, dc rms, ac rms) | |
Measuring range | 0 to 825 V dc or ac rms |
Autorange facility | 4 V / 40 V / 400 V / 750 V |
Resolution | 1 mV in 4 V range 10 mV in 40 V range 100 mV in 400 V range 1 V in 750 V range |
Accuracy: DC and dc rms | V > 1 V: ± 1 % rdg ± 5
digits V < 1 V: ± 0.02 V |
Accuracy: AVG | V > 1 V: ± 3 % rdg ± 5
digits V < 1 V: ± 0.03 V |
Accuracy: Pk | V > 1 V: ± 5 % rdg ± 5
digits V < 1 V: ± 0.03 V |
Accuracy: CF (Crest Factor) | 1.1 ≤ CF < 3: ± 3 % rdg ±
5 digits 3 ≤ CF < 5: ± 5 % rdg ± 5 digits Resolution: 0.01 |
Accuracy: RPL (Ripple) | 2 % ≤ RPL < 100 %: ± 3 %
rdg ± 5 digits 100 % ≤ RPL < 600 %: ± 5 % rdg ± 5 digits Resolution: 0.1 % Vdc > 0.5 V, Vac > 0.2 V |
All measurements dc and
15 Hz to 1 kHz Maximum overload 1,000 V rms Volts rms is a true-rms measurement (ac + dc) |
Harmonics | |
THD (Total Harmonic Distortion) | 1 % ≤ THD < 100 %: ± 3 %
rdg ± 5 digits 100 % ≤ THD < 600 %: ± 5 % rdg ± 5 digits Resolution: 0.1 % |
DF (Distortion Factor) | 1 % ≤ DF < 100 %: ± 3 %
rdg ± 5 digits Resolution: 0.1 % H02 ≤ Vharm < H13: ± 5 % ± 2 digits H13 ≤ Vharm ≤ H30: ± 10 % ± 2 digits |
All measurements up to 30th harmonic
(40th harmonic for 15 Hz to 22 Hz) Frequency range of fundamental F0 15 Hz to 22 Hz and 45 Hz to 65 Hz Vacrms > 1V |
Watts measurement (single- and three-phase) (dc, dc rms, ac rms) | |
Measuring range | 0 to 1650 kW dc or 1200 kW ac |
Autoranging facility | 4 kW, 40 kW, 400 kW, 1650 kW |
Resolution | 1 W in 4 kW 10 W in 40 kW 100 W in 400 kW 1 kW in 1200 kW |
Accuracy | 2.5 % rdg ± 5 digits W1Ø < 2 kW ± 0.08 kW W3Ø < 4 kW ± 0.25 kW |
VAR measurement (single- and three-phase) | |
Measuring range | 0 to 1250 kVAR |
Autorange facility | 4 kVAR, 40 kVAR, 400 kVAR, 1200 kVAR |
Resolution | 1 VAR in 4 kVAR 10 VAR in 40 kVAR 100 VAR in 400 kVAR 1 kVAR in 1200 kVAR |
Accuracy | VAR > 4 kVAR: ± 2.5 % rdg
± 5 digits VAR < 4 kVAR: ± 0.25 kVAR |
Power factor range | 0.3 < PF < 0.99 |
Power factor (single- and three-phase) | |
Measuring range | 0.3 capacitive to 1.0 and 1.0 to 0.3 inductive (72.5° capacitive to 0° and 0° to 72.5° inductive) |
Resolution | 0.001 |
Accuracy | ± 3° |
Frequency range | 15 Hz to 1 kHz |
Kilowatt hour (kWHr) | ||
Measuring range | 40,000 kWHr | |
Autorange facility | 4 kWHr, 40 kWHr, 400 kWHr, 4,000 kWHr, 40,000 kWHr | |
Resolution | 1 WHr in 4
kWHr Range 10 WHr in 40 kWHr Range 100 WHr in 400 kWHr Range 1 kWHr in 4,000 kWHr Range 10 kWHr in 40,000 kWHr Range |
|
Accuracy | kWHr > 2 kWHr:
± 3 % ± 5 digits kWHr < 2 kWHr: ± 0.08 kWHr |
|
All Watts /VA /VAR /PF measurements | Frequency range: | DC and 15 Hz to 1 kHz |
Current range: | 10 A to 1400 A rms | |
Voltage range: | 1 V to 825 V rms | |
Maximum input: | 825 V rms/1400 A rms | |
Maximum overload: | 1000 V rms/10,000 A All measurements dc and 15 Hz to 1 kHz. Maximum overload 10,000 A or rms x frequency < 400,000 |
Frequency measurement (from current or voltage sources) | |
Measuring range | 15 Hz to 1 kHz |
Resolution | 0.1 Hz |
Accuracy | 15 to 22 Hz ± 0.5 % rdg 40 Hz to 70 Hz ± 0.5 % rdg 15 Hz to 1000 Hz ± 1% rdg |
Current range | 10 A to 1400 A rms |
Voltage range | 1 V to 825 V rms |
Scope function | ||
Current measurement | Ranges: | 10 A / 20 A / 40 A / 100 A / 200 A / 400 A / 1000 A / 2000 A |
Resolution: | 1 A in 40 A 10 A in 400 A 50 A in 2000 A |
|
Accuracy: | ± 3 % rdg ± 1 pixel | |
Maximum overload: | 10,000 A | |
Voltage measurement | Ranges: | 4 V / 10 V / 20 V / 40 V / 100 V / 200 V / 400 V / 1000 V |
Resolution: | 100 mV in 4 V 1 V in 40 V 10 V in 400 V 31.25 V in 1000 V |
|
Accuracy: | ± 2 % rdg ± 1 pixel | |
Maximum overload: | 1000 V rms | |
Frequency range: | DC and 15 Hz to 600 Hz | |
Time base | 2.5 ms, 5 ms, 10 ms, 25 ms, 50 ms/div | |
Refresh rate | 0.5 seconds | |
Maximum sampling rate | 15.625 kHz |
Inrush current function | |
Ranges | 40 A, 400 A, and 2000 A |
Resolution | 10 mA in 40 A range 100 mA in 400 A range 1 A in 2000 A range |
Accuracy | I > 10 A: ± 5 % rdg ± 1
pixel I < 10 A: ± 0.5 A All measurements dc and 15 Hz to 1 kHz |
Maximum overload | Maximum overload 10,000 A
or rms x frequency < 400,000 Amps rms is a true-rms measurement (ac + dc) |
Capture time | 1 s, 3 s, 10 s, 30 s, 100 s, and 300 s |
Maximum sampling rate | 15.625 kHz |
Interface |
USB Interface to a PC |
Power Log software for download, analysis and reporting |
345 Upgrade Utility for installing a new firmware version |
Fluke Tester Related Items | |||||||
![]() Electrical Tester |
![]() Clamp-On Meters |
![]() Multimeter Tester |
![]() Thermometer Tester |
![]() Power Tools |
![]() Insulation Tester |
![]() Portable Oscilloscopes |
![]() Fluke Accessories |
Related Items | ||
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
Company Information Contact Us Customer Reviews Security Certifications Line Card - PDF |
Customer Service Return Policy Shipping & Delivery Process Frequenty Asked Questions Price Match |
Coupons and Specials Promotional Coupons Free Ground Shipping Limited Time Offers Buyer Protection |
![]() |
|
|
|
|