Voltage drop has an
important impact on LVL systems. Voltage drop occurs along the
length of cable and lamps at the end of run dimmer at the beginning.
Voltage drop is a function of cable length, cable size, and total
fixtures wattage. Voltage drop can be minimized in several different
ways:
BUY MORE SAVE MORE $ | |||||||
Cable Size | Cable Constant | 50W | 100W | 150W | 200W | 250W | 300W |
12-2 | 7500 | 300' | 150' | 100' | 75' | 60' | ----- |
10-2 | 11920 | 475' | 240' | 160' | 120' | 100' | 80' |
8-2 | 18960 | 750' | 380' | 250' | 190' | 150' | 125' |
100 ft. | 200 ft. | 300 ft. | 400 ft. | 500 ft. |
----- | ----- | ----- | ----- | 8-2 Low Voltage Wire |
10-2 Low Voltage Wire | 10-2 Low Voltage Wire | 10-2 Low Voltagee Wire | 10-2 Low Voltage Wire | 10-2 Low Voltage Wire |
12-2 Low Voltage Wire | 12-2 Low Voltage Wire | 12-2 Low Voltage Wire | 12-2 Low Voltage Wire | 12-2 Low Voltage Wire |
14-2 Low Voltage Wire | 14-2 Low Voltage Wire | 14-2 Low Voltage Wire | 14-2 Low Voltage Wire | 14-2 Low Voltage Wire |
![]() |