> Fluke Basic Electrical Tester
>
Fluke T+ Electrical Testers
Safer than traditional solenoid testers and fully compliant with NFPA 70E*
The T+PRO and T+ Electrical Testers offer all the
functionality that electricians look for in volt meters and voltage and
continuity testers:
- Both have three ways to detect ac/dc voltage: light, sound, and
vibration
- Both offer the added functionality of a GFCI trip and continuity beeper,
plus the convenience of a built-in flashlight
- The T+PRO Electrical Tester comes with a rotary field indicator for
troubleshooting three-phase systems, resistance measurement to 9.99 KOhms,
as well as a backlit LCD display for easier viewing
Safer than traditional solenoid testers:
- Solid-state tester design
- CAT IV 600 V, CAT III 1000 V rated
- Complies with NFPA 70E*
The ruggedness and reliability that customers have come
to expect from Fluke
* When used properly per Article 110.9 Use of Equipment (A) Test Instruments and
Equipment.
Features and benefits of the T+PRO and T+:
- 3 forms of ac/dc voltage indication: light, sound, and vibration for
added user protection and convenience
- Detect live voltage even when the batteries are dead
- Extra heavy-duty, replaceable test leads for more flexibility and
durability
- CAT IV 600 V, CAT III 1000 V rated for added user protection
- Continuity beeper
- Bright LED flashlight for work in poorly lit areas
- GFCI Trip
- On/Off switchable beeper, selectable according to your environment
- Compliant with latest NFPA 70E recommendations*
- Replaceable test probes for added flexibility and convenience
- Convenient probe storage on the back
- Probe holder for easier testing
- Hazardous voltage warning light for added user protection
- Test lead strap included for better test lead management
- AC/DC Voltage: 12 V – 600 V on LED bar, 10.2 V – 600 V on LCD (LCD on
T+PRO only)
- Auto-off saves battery power
- 2-year warranty
| Specifications |
| Temperature |
Operating |
-10 °C to 55 °C (14 °F to 131 °F) |
| Storage |
-30 °C to 60 °C (-22 °F to 140 °F) |
| Relative humidity |
0 °C to 30 °C (32 °F to 86 °F): 90 % |
| 30 °C to 40 °C (86 °F to 104 °F): 75 % |
| 40 °C to 50 °C (104 °F to 122 °F): 45 % |
| Altitude |
Operating |
2,000 m (approx. 6,561.6 ft) |
| Storage |
10,000 m (approx. 32,808.4 ft) |
| Battery type/life |
AAA (2); 40 hours |
| Shock, vibration |
Sinusoidal vibration per MIL-PRF-28800F
for a Class 2 instrument |
| Safety |
ISA-82.02.01 (IEC 61010-1 Mod) Second
Edition, CAN/CSA-C22.2 No. 61010-1 Second Edition, IEC 61010 - 1
to 1000 V CAT III/600 V CAT IV |
| Compliance to NFPA 70E* |
| AC Bandwidth |
45 Hz to 66 Hz |
| Maximum working voltage |
1000 V ac/dc |
| Maximum measurable voltage |
600 V ac/dc |
| Duty cycle |
Indefinitely for voltages up to 240 V
For voltages between 240 V and 600 V the duty cycle is 30 s on / 300 s
off
For voltages above 240 V the tester must connect to a voltage source
only for a MAXIMUM of 30 s and then disconnect for a MINIMUM of 300 s |
| Voltage hazard LED |
LEDs turn on at voltages > 30 V ac/dc ±
35 % |
| LED voltage indication levels |
12 V, 24 V, 48 V, 120 V, 208 V, 240 V,
277 V, 480 V, 600 V |
| LED voltage indication levels for
Canadian version |
12 V, 24 V, 48 V, 120 V, 208 V, 240 V,
347 V, 480 V, 600 V |
| LEDs |
LEDs turn on between 90 % and 100 % of
the indicated voltage on the LED, except for the 12 V LED which
turns on between 50 % and 100 % |
| LCD Resolution |
0.1 V for voltages < 50 V, 1 V for
voltages ≥ 50 V |
| 0.01 kΩ for resistance measurement (For
T+PRO Only) |
| GFCI Test current |
100 V - 150 V @ 6 mA - 9 mA ac, 150 V -
240 V < 12 mA |
| Standard input test current |
< 5 mA |
| Size (HxWxL) |
1.3 in x 2.15 in x 7.6 in (3.3 cm x
5.46 cm x 19.3 cm ) |
| Weight |
9.9 oz (0.28 kg) |
*When
used properly per Article 110.9 Use of Equipment (A) Test Instruments and
Equipment.
|