Fluke Electronics
Home
>
Fluke Electronics
> Basic Electrical Tester
> Fluke T3 Electrical Tester
The new Fluke T3 voltage and
continuity tester is easy-to-use iit's built to last. There are no buttons to
push or knobs to turn, just touch the test probes together and it automatically
turns on. The auto-on light at the top let's you know that it's working and will
automatically turn off after approximately eight minutes of inactivity. Seven
different voltage indicators will clearly differentiate between key voltage
levels.
|
Features
at a GlanceCompact and rugged, easily fits into a tool pouch
Protected to 1000 V for use in CAT III environments, and to 600 V for
use in CAT IV environments
Auto-on light lets you know that it’s working
LEDs clearly indicate seven ac and seven dc nominal voltage levels
DC polarity indicator
Automatically switches to continuity beeper or voltage measurement mode
Conserves battery power with auto-off feature
One-year warranty
|
|
Technical Specifications |
|
Electrical |
|
Voltage LED:
|
On at between 70% and 100% of marked voltage
|
|
Continuity threshold:
|
Beeper on at <20,000 W
|
|
Input impedance:
|
750 kW nominal.
|
|
AC frequency response:
|
45 Hz to 66 Hz
|
|
Battery:
|
(2) AA Life: 250 hours
|
|
|
Environmental Requirements |
|
Operating temperature:
|
14 °F to 122 °F (-10 °C to 50 °C )
|
|
Storage temperature:
|
-22 °F to 140 °F
(-30 °C to 60 °C ) |
|
Humidity:
|
0% to 95% - 32 °F to
86 °F (0 °C to 30 °C)
0% to 75% - 86 °F to 104 °F (30 °C to 40 °C )
0% to 45% - 104 °F to 122 °F (40 °C to 50 °C ) |
|
Dust/water resistant:
|
IP52 per IEC 529, no
vacuum applied |
|
Operating Altitude:
|
approx. 9,800 ft.
(3,000 m) |
|
|
Mechanical |
|
Size:
|
1.3” H x 1.8” W x
6.3” L (3.3 cm x 4.6 cm x 16 cm) |
|
Weight:
|
8 oz. (227 g ) with
batteries |
|
|
Safety |
|
Maximum operating voltage:
|
1000 V ac/dc between
any terminal and earth ground (protection only) |
|
Voltage rating:
|
Complies with IEC
1010-1 to 1000 V; OVERVOLTAGE Category III, Pollution Degree 2, and with
IEC 664-1 to 600 V; OVERVOLTAGE Category IV, Pollution Degree 2.* |
|
Agency approvals:
|
UL, CSA, CE, VDE
(pending) |
|
Inst Sheet - PDF
Calibration Manual - PDF
This item has been discontinued by Fluke.
Please click here
for the replacement
|