Home
>
Fluke Electronics
> Fluke Clamp Meters
> Fluke 902 True-rms HVAC Clamp Meter
Heating, ventilation, air conditioning (HVAC)
technicians require a service tool that can consistently keep up with their
demands. The Fluke 902 expands the exisiting line of quality Fluke clamp meters
by delivering the features necessary to diagnose and repair HVAC systems.
Combined with True RMS technology and a CAT III 600 V rating, the Fluke 902
helps technicians do their jobs safely and accurately.
The new Fluke 902 True RMS HVAC Clamp Meter
provides the accuracy, reliability and ruggedness that defines Fluke test tools.
It is designed for HVAC technicians for the systems they service and install
daily. With True RMS technology and a CAT III 600V rating, HVAC technicians can
troubleshoot and maintain HVAC equipment safely and with confidence in the
results.
Use the Fluke 902 to get more done:
- Capture flue gas temperatures
- Conduct flame rod testing
- Measure start and run motor capacitors
- Measure supply side current and voltage as well as load side current and
voltage
- Measure current and voltage phase balance on 3 phase systems
- Troubleshoot compressor electrical motor faults
- Measure performance of variable frequency drives
Features:
- Designed for HVAC applications with capacitance, DC Current (µA), and
temperature measurements
- Small body and jaws fit perfectly in your hand and into tight places
- Handy 'Display Hold' button keeps measurements on the display
- Meter controls are positioned so current measurements can be done with
one hand (index finger on clamp opening lever and thumb on rotary switch)
- Large, backlit display is easy-to-see in less than ideal conditions
- Auto shut-off maximizes battery life so the meter works when you need it
- Three year warranty
| Specifications |
| Voltage DC |
Range |
0 – 600.0 V |
| Accuracy |
1% ± 5 counts |
| Voltage AC (True RMS) |
Range |
0 – 600.0 V |
| Accuracy |
1% ± 5 counts (50/60 Hz) |
| Current AC (True RMS) |
Range |
0 – 600.0 A |
| Accuracy |
2.0% ± 5 counts (50/60 Hz) |
| Current DC |
Range |
0 - 200.0 µA |
| Accuracy |
1.0% ± 5 counts |
| Resistance |
Range |
0 – 9999 Ω |
| Accuracy |
1.5% ± 5 counts |
| Continuity |
<= 30 Ω |
Temperature*
(Type K Thermocouple) |
Range |
-10 degree C to 400 degree C (-14
degree F to 752 degree F) |
| Accuracy |
+/- 1.0% + 0.8 degree C (+/- 1.0% + 1.5
degree F) typical |
| Range |
-40 degree C to -10 degree C (-40
degree F to -14 degree F) |
| Accuracy |
+/- 5.0% + 1.5 degree C (+/- 5.0% + 3.3
degree F) typical |
| Capacitance |
Range |
1-1000 µF |
| Accuracy |
1.9% ± 2 counts |
* Error does not include Type K Thermocouple
errors
| Mechanical & General
Specifications |
| Weight |
1.5 lbs (.7 kg) |
| Dimensions |
10.75” x 4.25” x 2.44” (27.3 cm x 10.8
cm x 6.2 cm) |
| Battery type |
(2) AA Alkaline Batteries |