pad

Click to enlarge

Cadet Heater "CEH" Industrial Unit Electric Heater

Home > Exhaust Fan > Cadet Heater >"CEH" Industrial Unit Electric Heater

CEH :Industrial  Unit Heater
 

Features and Benefits :

  • Manual reset thermal protection

  • Commercial grade high temperature manual reset with 25 amp rating at 240 Volt

  • High mass, tubular element for longer life

  • Fan delay eliminates cold draft on startup and disperses residual heat on shutdown

  • Rugged die formed construction for durability

  • Wire single or three phase to suit the application

  • Mounts vertically or horizontally

  • 5 Year Warranty
     

General Information:
Calculate the heat loss of the area to be heated. It is recommended that one of the following methods be used: ASHRAE Guide and Data Book ( The  American Society of Heating , Refrigeration & Air Conditioning Engineers) ; The NEMA Handbook ( The National Electrical Manufacturer's Association); or the ACCA Manual J (The Air Conditioning Contractors of America). The layout of the space to be heated must be taken into consideration to determine the selection of the best size and air displacement. Most applications benefit from a combination of vertically and  horizontally  discharged air delivery. In  buildings with large doors that are frequently opened, use  a high  velocity heater with horizontal air flow across the opening, or use an infrared heater.  In smaller areas where comfort is a prime consideration,  more heaters of smaller capacity are recommended. Smaller KW heaters are also recommended for low mounting heights to avoid discomfort and increased noise levels. Additionally, there is better air distribution by using a greater number of lower KW heaters.

Horizontal Air Flow - Position  heaters to allow the air flow  to "wipe" the exposed walls without blowing directly against  the wall. Spacing between the heaters should be approximately 1.5 times the "air throw" of the heaters (Approx air throw 12') .

Vertical Air Flow - When vertical discharging heaters are used exclusively, the air streams must overlap to blanket outside walls to provide good heat distribution. Vertical air flow is best used for areas with high ceilings or bays. Vertical discharging units are to be mounted high above machinery, assembly lines, etc. Vertical discharging units are best used when the perimeter heat loss is adequately controlled.

Architectural Information:
Fan forced unit heater shall be UL Listed and rated at 208, 240, 277 or 480 Volt. Horizontal or vertical mounting shall be possible to direct discharged air. External cabinet shall be constructed of 20 gauge high quality steel. All metal surfaces of the cabinet, external and internal, shall be finished with a baked on powder coat paint system. Fan shall be aluminum blade axial flow type, and mounted directly to the motor shaft. Motor shall be shaded pole, industrial rated, with an inherent overheating protection device. Heating elements shall be sealed in magnesium powder and protected by metal sheathing, over which aluminum fins are applied. Heater shall be equipped with manual reset thermal cut out for over temperature protection. Fan motor circuit shall be thermostatically controlled, allowing fan to remain operating after the elements have shut off, discharging the residual element heat. Wiring compartment shall have convenient access door with captured hardware.


Technical Information:
Heater is constructed of 22 gauge steel for durability and powder coated for a quality finish. Baseboard heaters work best when placed under a window and at least 12" from furniture or other objects. Keep at least 12" minimum from objects hanging above (i.e., drapes). Heater may be placed directly on the floor and mounted to the wall. (Left end wiring only).


Product Dimensions:
16"H x 14"W x 8.25"D

 Ordering Information:

To order units with FACTORY INSTALLED OPTION 24 Volt Control Package, add the following suffix numbers to CEH: Suffix No. - B.
The 24 Volt control package includes a transformer and contactor. It is required to change from line voltage control to 24 Volt control for the following model numbers: CEH003-M, CEH003-P, CEH003-R, CEH005-M, CEH005-P, and CEH005-R. Units with the "B" package (whether included or added as an option) require a low voltage thermostat (see T810D - part number 72820).

NOTE: 24 Volt control is needed when controlling several heaters with one thermostat. 24 Volt control is standard on all 480V
models.

Ordering Example:
CEH003-MB (Includes 24 Volt control package)

*Models CEH003-M, P, R and CEH005-P, R (1 Phase) are designed to use a C600M, C600S or a CEKTB2 thermostat. If you add the jumpers, as shown on the heater wiring diagram (supplied with instructions and in wiring compartment) you can use a Single Pole 22 amp stat or a CEKTB1 thermostat. USE ONLY C600M, C600S, OR A CEKTB2 FOR 3 PHASE.


** When using model number CEH-005-M wired 1 phase (factory wired) use the following thermostats:
Wall Mount - C611-25,
Built-In - CEK-TB2 (two-stage thermostat)

Approximate air throw is 12'. The CEH is recommended for elevations under 7500 feet.




pad
padCadet CEH003-P 240V Industrial Unit Heater
pad
$305.50
pad
padCadet CEH003-R 277V Industrial Unit Heater
pad
$305.50
pad
pad
padCadet CEH003-SB 480V Industrial Unit Heater
pad
$382.20
pad
padCadet CEH005-P Industrial Unit Heater
pad
$305.50
pad
pad
padCadet CEH005-R Industrial Unit Heater, 277 Volt
pad
$305.50
pad
padCadet CEH005-SB Industrial Unit Heater, 480 Volt
pad
$382.20
pad
pad
padCadet CEH003-M Industrial Unit Heater
pad
$305.50
pad
padCadet CEH005-M Industrial Unit Heater
pad
$305.50
pad
pad
padCadet "CEH" Series Accessories
pad
pad

PROMO ITEMS
Cadet Heater
Markel Heater
Christmas Lights

Lasko Heater

Cadet Heater, Markel Heater, Christmas Lights

Lasko Heater
PROMO ITEMS
Cadet Heater
Markel Heater
Christmas Lights

Lasko Heater

We now ship to APO, FPO, and World Wide International Shipping. Please click here.

Dimmers | Lutron Spacer System Dimmers | Lutron Skylark Dimmers | Lutron Maestro Dimmers | Lutron Maestro Satin Dimmers | Lutron Diva Dimmers | Lutron Diva Satin Dimmers | Lutron Faedra Dimmers | Lutron Grafik Eye | Lutron Athena Dimmers | Lutron Centurion Rotary | Lutron GrafikRA Dimming Controls | Lutron RadioRA Lighting Control | Lutron Qoto Dimmers | Lutron Nova Dimmers | Lutron Nova T Dimmers | Lutron Dimmers | Lutron Dimmer Selection Guide | Leviton Switches | X10 PRO | Lutron Wiring Devices | Lutron Wallplates | Lutron Claro Screwless Wallplates | Lutron Fassade Screwless Wallplates | Electronic Testers | Fluke Testers | Amprobe Testers | Gardner Bender Testers | Greenlee Testers | Ventilation Fans | Ceiling Fan | Nutone Fan | Fantech Fan | Panamex Fan | Air King Fan | Exhaust Fan Guide | Dryer Booster Fan | Fantech Premium Bathroom Fan | Fanimation Ceiling Fan | Westinghouse Ceiling Fan | Progress Ceiling Fan | Ceiling Fan Selection Guide | Light Bulbs | HID Light Bulbs | Halogen MR16 Light Bulbs | Halogen PAR Lamps | Incandescent BR Lamps | Light Bulbs Consumer Guide | Landscape Lighting Transformer | Corona Directional Landscape Lighting | Corona Area Landscape Lighting | Corona Path Landscape Lighting | Corona Tree Landscape Lighting | Focus Landscape Area Lighting | Focus Landscape Path Lighting | Focus Landscape Hanging Lighting | Focus Landscape Step Lighting | Focus Underwater Lighting | Focus Landscape Compact Fluorescent Lighting | Dabmar Landscape Directional Lighting | Dabmar Landscape Area Lighting | Dabmar Landscape Path Lighting | RAB Landscape Lighting | Vista Pro Landscape Lighting | Malibu Low Voltage Landscape Lighting | Malibu Solar Landscape Lighting | Kichler Low Voltage Path Landscape Lighting | Kichler Line Voltage Landscape Lighting | Progress Landscape Lighting | Landscape Lighting Installation Guide | Landscape Low Voltage Wires | TechnoMagnet Transformer | GE Transformer | Light Tech Transformer | Intermatic Transformer | Lightcraft Transformer | Transformer Selection Guide | Lighting Products | Under Cabinet Lighting | Murray Feiss Lighting | Access Lighting | Westinghouse Lighting | Zaneen Lighting | Kichler Lighting | Progress Lighting | Besa Lighting | Ark Lighting | RAB Lighting | Eurofase Lighting | Hampstead Lighting | Tech Lighting| Tiffany Lamps | FSC Under Cabinet Lighting | Juno Under Cabinet Lighting | WAC Under Cabinet Lighting | Kichler Under Cabinet Lighting | Recessed Lighting Track Lighting | Liton Recessed Lighting | Halo Recessed Lighting | Juno Recessed Lighting | Elco Recessed Lighting | WAC Recessed Lighting | DMF Recessed Lighting Liton Track Lighting | Halo Track Lighting | Juno Track Lighting | Elco Track Lighting | WAC Track Lighting | DMF Track Lighting | PLC Track Lighting | Smoke Alarms | Timers | BRK Smoke Alarm | Firex Smoke Alarm | Firex Carbonmonoxide Detector | Kidde Smoke Alarm | Smoke Alarm Catalog | Intermatic Timer | Intermatic In Wall Mechanical Timer | Intermatic In Wall Electronic Timer | Leviton Timer

Yahoo! Buyer Protection Program ecommerce provided by Yahoo! Small Business HACKER SAFE certified sites prevent over 99.9% of hacker crime.
Yahoo! Buyer Protection Program